Look for in ASME B31.4, there is the tolerance for ovality.
The better way to inspect or verify the ovality is passing a wood circular plate inside pipes pipes, the diameter of the plate has to be the stablished according to the ASME B31.4 tolerance for ovality.
Thanks and regards
From: eduardocalva@hotmail.com
To: materials-welding@googlegroups.com
Subject: [MW:8610] Mechanized welding process and pipe ovality
Date: Wed, 8 Dec 2010 20:28:04 -0600
Dear all, I'd like to know what's the better pipes ovality tolerance in order to use a Mechanized welding process in pipelay?
And what's the better way to inspect or verify the ovality.
Thanks
Eduardo Calva
--
To post to this group, send email to materials-welding@googlegroups.com
To unsubscribe from this group, send email to materials-welding+unsubscribe@googlegroups.com
For more options, visit this group's bolg at http://materials-welding.blogspot.com/
The views expressed/exchnaged in this group are members personel views and meant for educational purposes only, Users must take their own decisions w.r.t. applicable code/standard/contract documents.
No comments: