Dear Murali,
Welder is not eligible for 2".
Should be done separately.
On Wed, 9 Sep 2020, 06:57 Murali Krishnan, <muraligkrishnan@gmail.com> wrote:
Greetings,I have a weldolet 2" NPS X OD 82 mm, I want to use the welder qualified for 2 7/8 (73 mm) & over.Query initiated by client that as per ASME SEC IX Table QW 452.3 foot note (b) states that 2 7/8 in. (72mm) O.D. is the equivalent of NPS 2 1/2 (DN 65). In this case the welder client says welder is not qualified for 2 inch NPS.since the welder qualification essential variable is OD inline with ASME SEC IX, kindly advice.If any reference kindly share the same.Thanks--Murali--Thanks and Best Regards,G.Murali krishnan