In one of our project, G28 Method A for Inconel 625 pipes (B444) didnt met the accpetance criteria - (one sample didnt meet in the weight loss requirement) and other didnt meet the 50X magnification requirement.
The supplier is cross referring to MR0175 Part C and requesting for retesting. But is MR0175 right document to cross refer? Any thoughts?
Regards
Nitin
-- https://materials-welding.blogspot.com/
https://www.linkedin.com/groups/122787
---
You received this message because you are subscribed to the Google Groups "Materials & Welding" group.
To unsubscribe from this group and stop receiving emails from it, send an email to materials-welding+unsubscribe@googlegroups.com.
To view this discussion on the web visit https://groups.google.com/d/msgid/materials-welding/cd8705e4-5718-4ace-b75c-8adc3dc95402n%40googlegroups.com.