Thursday, April 2, 2020

[MW:30686] Re: AWS D1.1 _2010- Table 4.1,4.5 & 4.6-WPS/PQR -Production Qualification Range

PQR Qualified 3G Position

WPS Qualified vertical only position 

as per AWS D1.1... again qualified every position PQR & WPS

On Tuesday, 13 October 2015 15:40:56 UTC+3, Anban wrote:
Dear Sirs

Pls advise

Table 4.1- WPS/PQR qualified in 3G Position=

Production Plate Welding Qualified - Groove CJP/PJP & Fillet - Vertical only


Production Pipe Welding Qualified - Butt Joint - CJP/PJP( Outside Dia 20" and above ) - Vertical only


Production Box Tube Welding Qualified- Fillet - Vertical only


Table 4.5 #27) A change in position not qualified by Table 4.1- Require New WPS/PQR Qualification


Table 4.5 #30) Vertical Welding: For any pass from uphill to downhill or vice versa-Require New WPS/PQR Qualification


Whereas in Table 4.6-PQR Supplementary Essential Variable Changes for CVN Testing Applications Requiring WPS Requalification for SMAW, SAW, GMAW, FCAW, and GTAW

Table 4.6 -Position # 6 -A change in position to vertical up. A 3G vertical up test qualifies for all positions and vertical down.

In my opinion both Table 4.1 & 4.5 contradicts with Table 4.6 # 6  Statement.

My understanding is if my WPS/PQRs qualified with certain CVN testing in 3G position, I can use it for for all Prodiction weld positions -Plan , Horizontal, Vertical-Up, Vertical down and Overhead weld positions.


Thanks

--
https://materials-welding.blogspot.com/
https://www.linkedin.com/groups/122787
---
You received this message because you are subscribed to the Google Groups "Materials & Welding" group.
To unsubscribe from this group and stop receiving emails from it, send an email to materials-welding+unsubscribe@googlegroups.com.
To view this discussion on the web visit https://groups.google.com/d/msgid/materials-welding/4a99a5b8-ea60-40fa-90e3-e8606692afa9%40googlegroups.com.

No comments:

Re: [MW:35289] Welding consumable for S355J2WP material

S355 J2 WP  is a weathering structural steel  It has better atmospheric corrosion resistance. Use E 8018 - W1/W2  Electrodes This is regular...