Sunday, September 23, 2018

Re: [MW:28327] testing of inaccessible welded joints

If it is a pipe line, best option is to do hydro test with 1.25 times of the working pressure to ensure the integrity 
Also can go with ultrasonic pig in case of pig possible lines

Thanks and Regards 
Lakshman kumar. B 
+91 9440031459

Sent from my iPhone

On 23-Sep-2018, at 11:28 AM, Ali Asghari <asgharialigl@gmail.com> wrote:

Dear All.

Does anybody know there is NDT method that can inspected welded joints which are buried and not accessible?our concern is about finding of construction defects either surface and internal that have a good detect ability for linear ones particularly Transverse Crack.

Regards.
 

--
https://materials-welding.blogspot.com/
https://www.linkedin.com/groups/122787
---
You received this message because you are subscribed to the Google Groups "Materials & Welding" group.
To unsubscribe from this group and stop receiving emails from it, send an email to materials-welding+unsubscribe@googlegroups.com.
Visit this group at https://groups.google.com/group/materials-welding.
For more options, visit https://groups.google.com/d/optout.

No comments:

Re: [MW:35289] Welding consumable for S355J2WP material

S355 J2 WP  is a weathering structural steel  It has better atmospheric corrosion resistance. Use E 8018 - W1/W2  Electrodes This is regular...