On Friday, 24 August 2018 19:28:41 UTC+5:30, Chiranjeevulu Temburu wrote:
-- As Impact testing is required, which become as supplementary essential variable, hence you need a another WPS. For qualifying this WPS (P1 G1 to P1 G2), You have two options,
1. If you have earlier Qualified PQR of P1 G1 to P1 G2, the same may be used as to supporting PQR for the WPS
2. You need to qualify separate PQR.
Regards
Aakash
On Friday, 24 August 2018 19:28:41 UTC+5:30, Chiranjeevulu Temburu wrote:
Dear Experts,1. WPS/PQR (P NO: 1, Group No-1 to P NO: 1, Group No-1 ) is available with contractor2. Pipe material: ASTM A333 Gr.6 (P No: 1, Group No: 1)
Flange/Fitting material: ASTM A350 Gr.LF2 CL.1 (P No: 1, Group No: 2)
WPS/PQR ( P NO: 1, Group No-1 to P NO: 1, Group No-2 ) is not available with contractor3. Charpy "V" notch test to be doneMy query isCan I use WPS/PQR P NO-1, Group NO-1 (PLATE) to P NO-1, Group NO-2 (PLATE) for welding of ASTM A333 Gr.6 (P No: 1, Group No: 1) to ASTM A350 Gr.LF2 CL.1 (P No: 1, Group No: 2) ?Please give suggestions, Is it possible in accordance with ASME Section-IX ?CHIRANJEEVULU TEMBURU l Inspection Engineer-Mechanical I +918790956353.