Dear James,
Your reply on subject was really helpful. I just wanted to discuss a case of NACE MR0175
Suppose if Welding wire manufacturer (ER70S-2 & ER70S-6) has not specified any NACE compliance in MTC and if weld Zones meeting Hardness requirement of 250HV10 then does that STILL mean that we comply NACE requirements?
Also I would like to understand more of this statement; Welding consumables and procedures that produce a deposit containing more than 1% nickel are acceptable after successful weld SSC qualification by testing in accordance with Annex B. But what if Nickel is less than 1%? Does that mean that SSC is not required if Nickel is less than 1% ?
Would love to hear from you
Regards,
Ankur
7990344780
ankurpandey25@gmail.com
On Tuesday, February 8, 2011 at 10:41:08 PM UTC+5:30, viral talati wrote:
On Tuesday, February 8, 2011 at 10:41:08 PM UTC+5:30, viral talati wrote:
Dear Friends,
Is there any special requierment for electrode used for NACE material welding.regards
https://materials-welding.blogspot.com/
https://www.linkedin.com/groups/122787
---
You received this message because you are subscribed to the Google Groups "Materials & Welding" group.
To unsubscribe from this group and stop receiving emails from it, send an email to materials-welding+unsubscribe@googlegroups.com.
Visit this group at https://groups.google.com/group/materials-welding.
For more options, visit https://groups.google.com/d/optout.
No comments:
Post a Comment