Monday, November 30, 2015

[MW:23935] Re: tensien test

if the breaking  tensile strength is more than the base metal, then no problem
In PQR , write that "Fracture in Weld "
that's all

On Sunday, November 8, 2015 at 9:43:31 AM UTC+5:30, ahmed boh wrote:
Hi,
I am working in pipeline project API1104.
I heve one speciemen breaks on the weld in tension test for mechanized welding operator with filler metal and the tension strength was greater the SMTS.

 pls advise what we should do in this case?
ahmed

--