I have encounter here in our project site after the welding of pipe to valve 6" sch160(18.26mm thk) the welding joint is misalignment of 5mm. My question is how can i raise a ncr for this because sch160 will not be distortion. Wht i will wrote in the ncr on this problem. And wht is the standard for this.
Regards
You received this message because you are subscribed to the Google Groups "Materials & Welding" group.
To unsubscribe from this group and stop receiving emails from it, send an email to materials-welding+unsubscribe@googlegroups.com.
To post to this group, send email to materials-welding@googlegroups.com.
Visit this group at http://groups.google.com/group/materials-welding.
To view this discussion on the web visit https://groups.google.com/d/msgid/materials-welding/1194034234.991572.1446887133387.JavaMail.yahoo%40mail.yahoo.com.
For more options, visit https://groups.google.com/d/optout.