Dear Mehdi,
Referring to AWS D1.1 Table 6.1 "Complete fusion shall exist between adjacent layers of weld metal and between weld metal and base metal" but if the joint welding symbol mentioned CJP, BG, FP then no acceptance criteria for LOP.
Best regards,
Tarek Yehia
Tarek Yehia
E-mail: t.yehia2009@gmail.com
Cell#: 00966 50 104 0991
00966 56 772 6160
Skype ID: eng.cardo@skype.com
Skype ID: eng.cardo@skype.com
On Sat, Oct 3, 2015 at 1:23 PM, Mehdi Vafakhah <mehdi.vafakhah@gmail.com> wrote:
Dear experts--
whats the L.O.P Visual Inspection Acceptance Criteria according to AWS D1.1 ?
Best regards
You received this message because you are subscribed to the Google Groups "Materials & Welding" group.
To unsubscribe from this group and stop receiving emails from it, send an email to materials-welding+unsubscribe@googlegroups.com.
To post to this group, send email to materials-welding@googlegroups.com.
Visit this group at http://groups.google.com/group/materials-welding.
To view this discussion on the web visit https://groups.google.com/d/msgid/materials-welding/60468822-24e4-4a64-8127-db4fde3a250a%40googlegroups.com.
For more options, visit https://groups.google.com/d/optout.
You received this message because you are subscribed to the Google Groups "Materials & Welding" group.
To unsubscribe from this group and stop receiving emails from it, send an email to materials-welding+unsubscribe@googlegroups.com.
To post to this group, send email to materials-welding@googlegroups.com.
Visit this group at http://groups.google.com/group/materials-welding.
To view this discussion on the web visit https://groups.google.com/d/msgid/materials-welding/CAOpHpqCXOcJbkanKpVsjZppbFt1P7i8mH0Hz1z3%3DeL%2Bb4LFwoA%40mail.gmail.com.
For more options, visit https://groups.google.com/d/optout.
No comments:
Post a Comment