[MW:22803] RE: 22800] Non conform ferrite on Duplex UNS31083

Hello Pedro,

 

When I'm right connections are made with GTAW root layers. In general you can have problems with corrosion resistance of your weld metal if ferrite content is to low but depends on the environment.

If only root layers are in contact with corrosive medium than this shouldn't be a problem if composition and ferrite content in GTAW weld metal complies with the project requirements.

If also SMAW weld metal is in contact with medium than you can/will have a corrosion issue.

 

Met vriendelijke groeten / Best Regards,

 

Herman Pieper

QA-QC Inspector / CSWIP + IWI-C Welding Inspector / IWT / Materials Expert

 

Job van der Havestraat 6

8384 DB, Wilhelminaoord

Cell: +31 6 51691215

 

Van: materials-welding@googlegroups.com [mailto:materials-welding@googlegroups.com] Namens Pedro JUNIOR
Verzonden: dinsdag 3 februari 2015 10:34
Aan: materials-welding@googlegroups.com
Onderwerp: [MW:22800] Non conform ferrite on Duplex UNS31083

 

Dear experts,

 

Ferrite content has been measured (24 to 29% measured in weld metal) below project requirements (30 to 55%). Counter tests demonstrated same values.

 

Most of our contractor's WPQRs are qualified with GTAW+SMAW processes for thicknesses over 14 mm.

In order to comply with their general practices, contractor decided to order duplex SMAW filler metal

After review of feedback of the contractor on ferrite content, it appears that ferrite % is quite low in general with SMAW. This feedback has not been clearly figured out on WPQR reports and production welds do not comply with our requirements (client requirements).

Welding monitoring have been done properly. General quality of the weld is good. The concern comes from the filler metal itself.

 

In case of acceptance.

 

è Which are the risk of accepting Ferrite Content below the minimal required for duplex?

 

Best Regards

 

Pedro JUNIOR

QC Piping Inspector

TOTAL E&P ANGOLA

DT/EPT/MHSAQ/QAQC
Tel : +244 222 67 2097

Cell:+244 912 641 681
Email:
pedro.junior@total.com

 

Mailing Address:

TOTAL E&P Angola

Rua 6 IL 6 B.I SONILS, Boavista Luanda

B.I- 100-Office 011

Luanda - Angola 

  

                                                  

 

 

--
You received this message because you are subscribed to the Google Groups "Materials & Welding" group.
To unsubscribe from this group and stop receiving emails from it, send an email to materials-welding+unsubscribe@googlegroups.com.
To post to this group, send email to materials-welding@googlegroups.com.
Visit this group at http://groups.google.com/group/materials-welding.
To view this discussion on the web visit https://groups.google.com/d/msgid/materials-welding/F259984E42C1CE448E2E2CE7084C2C5701282EAAE1CE%40AOEPTTA-EG11.main.glb.corp.local.
For more options, visit https://groups.google.com/d/optout.

Comments

Popular posts from this blog

Re: [MW:34105] SA266 GR4N 4 Cycle SPWHT

Hi,  You are correct, Minimum refers to the one cycle for which this part will expose until final work shop PWHT. hence mill test certificate shall include this.  Max. SPWHT, refers to additional cycles of heat treatment that are reserved for future repairs during equipment lifetime.  Again, these simulated no. Of cycles shall be specified in MTC.  The idea is we need to make sure that steel mechanical properties are not compromised upon exposure to multiple repairs (i e 4 cycles in your case).  One could say, if steel is subjected to 4 cycles and is ok, then it should by defacto be good for one cycle, yet, this is wrong assumption cause mechanical problems and microstructure of materials varies accordingly based on no. Of cycles for which material will expose. This is apparent in alloy steel and especially for impact test values as an example.  In your case, this forged CS with properties before PWHT can be understood to be " as forged" condition (i.e. Wit...

Materails FAQs

Q: What are equivalents for standard Q 235 B (and Q 235 A) for U-channels? (asked by: boris.vielhaber@vait.com) A: DIN Nr. = 2393 T.2, 2394 T.2, EN 10025 W. Nr. DIN 17007 = 1.0038 Design DIN 17006 = RSt 37-2, S235JRG2 (Fe 360 B) Q: What is St DIN 2391 BK material? (asked by: dmcandrews@automaticstamp.com) A: Precision steel tubes, cold-finished/hard. Q: What is C.D.W. Boiler Tube? (asked by: montydude123@yahoo.com) A: Cold Drawn Welded Boiler Tube. Q: WHAT IS W.Nr. 1.4301? PLS TELL US IN EASY LANGUAGUE (asked...

Heat tint (temper) colours on stainless steel surfaces heated in air // Heat tint

Introduction The colour formed when stainless steel is heated, either in a furnace application or in the heat affected zone of welds, is dependent on several factors that are related to the oxidation resistance of the steel. The heat tint or temper colour formed is caused by the progressive thickening of the surface oxide layer and so, as temperature is increased, the colours change.   Oxidation resistance of stainless steels However, there are several factors that affect the degree of colour change and so there is no a single table of colour and temperature that represents all cases. The colours formed can only be used as an indication of the temperature to which the steel has been heated. Factors affecting the heat tint colours formed Steel composition The chromium content is the most important single factor affecting oxidation resistance. The higher the chromium, the more heat resistant the steel and so the development of the heat tint colou...