[MW:22803] RE: 22800] Non conform ferrite on Duplex UNS31083

Hello Pedro,

 

When I'm right connections are made with GTAW root layers. In general you can have problems with corrosion resistance of your weld metal if ferrite content is to low but depends on the environment.

If only root layers are in contact with corrosive medium than this shouldn't be a problem if composition and ferrite content in GTAW weld metal complies with the project requirements.

If also SMAW weld metal is in contact with medium than you can/will have a corrosion issue.

 

Met vriendelijke groeten / Best Regards,

 

Herman Pieper

QA-QC Inspector / CSWIP + IWI-C Welding Inspector / IWT / Materials Expert

 

Job van der Havestraat 6

8384 DB, Wilhelminaoord

Cell: +31 6 51691215

 

Van: materials-welding@googlegroups.com [mailto:materials-welding@googlegroups.com] Namens Pedro JUNIOR
Verzonden: dinsdag 3 februari 2015 10:34
Aan: materials-welding@googlegroups.com
Onderwerp: [MW:22800] Non conform ferrite on Duplex UNS31083

 

Dear experts,

 

Ferrite content has been measured (24 to 29% measured in weld metal) below project requirements (30 to 55%). Counter tests demonstrated same values.

 

Most of our contractor's WPQRs are qualified with GTAW+SMAW processes for thicknesses over 14 mm.

In order to comply with their general practices, contractor decided to order duplex SMAW filler metal

After review of feedback of the contractor on ferrite content, it appears that ferrite % is quite low in general with SMAW. This feedback has not been clearly figured out on WPQR reports and production welds do not comply with our requirements (client requirements).

Welding monitoring have been done properly. General quality of the weld is good. The concern comes from the filler metal itself.

 

In case of acceptance.

 

è Which are the risk of accepting Ferrite Content below the minimal required for duplex?

 

Best Regards

 

Pedro JUNIOR

QC Piping Inspector

TOTAL E&P ANGOLA

DT/EPT/MHSAQ/QAQC
Tel : +244 222 67 2097

Cell:+244 912 641 681
Email:
pedro.junior@total.com

 

Mailing Address:

TOTAL E&P Angola

Rua 6 IL 6 B.I SONILS, Boavista Luanda

B.I- 100-Office 011

Luanda - Angola 

  

                                                  

 

 

--
You received this message because you are subscribed to the Google Groups "Materials & Welding" group.
To unsubscribe from this group and stop receiving emails from it, send an email to materials-welding+unsubscribe@googlegroups.com.
To post to this group, send email to materials-welding@googlegroups.com.
Visit this group at http://groups.google.com/group/materials-welding.
To view this discussion on the web visit https://groups.google.com/d/msgid/materials-welding/F259984E42C1CE448E2E2CE7084C2C5701282EAAE1CE%40AOEPTTA-EG11.main.glb.corp.local.
For more options, visit https://groups.google.com/d/optout.

Comments

Popular posts from this blog

Heat tint (temper) colours on stainless steel surfaces heated in air // Heat tint

Introduction The colour formed when stainless steel is heated, either in a furnace application or in the heat affected zone of welds, is dependent on several factors that are related to the oxidation resistance of the steel. The heat tint or temper colour formed is caused by the progressive thickening of the surface oxide layer and so, as temperature is increased, the colours change.   Oxidation resistance of stainless steels However, there are several factors that affect the degree of colour change and so there is no a single table of colour and temperature that represents all cases. The colours formed can only be used as an indication of the temperature to which the steel has been heated. Factors affecting the heat tint colours formed Steel composition The chromium content is the most important single factor affecting oxidation resistance. The higher the chromium, the more heat resistant the steel and so the development of the heat tint colou...

[MW:5202] RE: 5200] NDT after PWHT

------------------------------------- Interpretation:  I‑89‑14 Subject:         Section I (1986 Edition, 1987 Addenda), PW‑11,                  NDE Prior to PWHT Date Issued:     December 15, 1988 File:            BC88‑393   Question: Does PW‑11 require that NDE be performed on welds after they have been subjected to the postweld heat treatment required by PW‑39?   Reply: No, unless the conditions described in PW‑11.2.2 exist. ---------------------------------------------- Interpretation:  VIII-1-98-09 Subject:         Section VIII, Division 1 (1995 Edition, 1996 Addenda); NDE                 ...

Materails FAQs

Q: What are equivalents for standard Q 235 B (and Q 235 A) for U-channels? (asked by: boris.vielhaber@vait.com) A: DIN Nr. = 2393 T.2, 2394 T.2, EN 10025 W. Nr. DIN 17007 = 1.0038 Design DIN 17006 = RSt 37-2, S235JRG2 (Fe 360 B) Q: What is St DIN 2391 BK material? (asked by: dmcandrews@automaticstamp.com) A: Precision steel tubes, cold-finished/hard. Q: What is C.D.W. Boiler Tube? (asked by: montydude123@yahoo.com) A: Cold Drawn Welded Boiler Tube. Q: WHAT IS W.Nr. 1.4301? PLS TELL US IN EASY LANGUAGUE (asked...