As per the Sec IX, diameter is not essential variable. WQT done as per the PQR. Refer QW 256 for GTAW process. I hope you satisfy.
Pramodh ramanunny
Iraq badra oil feild
Sent from my iPad
Sent from my iPad
--Dear Experts,We have qualified PQR test coupon dia 2.5". but WPS not mentioned diameter range qualifiedContractor qualified WQT 1/2" Piping weld,accordingly welding has been done for 3/4" size pipe.Please provide your valuable suggestion to these welding accept or reject as per section 1X.Best Regards,Dominic V.K.
QA/QC-Inspector.