could you send your normalizing procedure?

    best regards

    Dr. Georgios Dilintas

    Authorized Nuclear Inspector
    Authorized Inspector Supervisor
    API 510 Inspector

    I&F REGIONAL TECHNICAL MANAGER
    BUREAU VERITAS HELLAS

    Tel: +30 210 40 63 113/4
    Fax: +30 210 40 63 118
    Cell: +30 69 44 64 62 04
    (See attached file: Dilintas_George.vcf)

Darapu Dattatreya ---18/12/2013 06:43:09---Dear Experts,  

From: Darapu Dattatreya <darapu_dattatreya@yahoo.com>
To: "materials-welding@googlegroups.com" <materials-welding@googlegroups.com>
Date: 18/12/2013 06:43
Subject: Re: [MW:19645] IMPACT TEST IN PTC AT -47 DEG
Sent by: materials-welding@googlegroups.com




Dear Experts,
 
We are facing Impact Test failures problem after Normalizing the pipe fittings manufactured Impact Tested SA 5416 Gr. 70 Material at - 46 deg. C
 
We have put a lot of pipe fittings in our normalizing furnace 25 mm thk. & 14 thk pipe fittings, after that we have selected one sample each thk and Impact tested, the 14 mm thk fitting the passing the Impact test requirement for parent metal, HAZ & Weld as per ASME B 31.3 & the other sample 25 mm thk. failing the Impact requirement on Parent metal & HAZ and the Impact value we have observed 8 , 10 & 12 etc. and the
 
Can any body explain the reason for the failures in Impact test requirements as per ASME B 31.1.
 
Regards,
 
D.Dattatreya.    


On Tuesday, December 20, 2011 10:16 PM, Dindo <dindodelacruz@gmail.com> wrote:
you have to monitor the actual welding of the coupon and make sure that you are within the parameters of the qualified WPS, if it still fails you can always send the coupon for stress relieving (which is more costly since you have to PWHT your vessel too)

On Mon, Dec 19, 2011 at 10:27 PM, Vivek Pandey <vivek.pande06@gmail.com> wrote:
    DEAR EXPERTS

    AT this time Iam facing a critcal problem in impact test at minus 47
    deg. I have a already existing qualified PQR WITH E 8018G & IMPACT
    Tested at -47deg. I have used the same PQR in  vessel production test
    at -47deg but this PTC has failed in imapct test of WELD & HAZ at
    -47deg we are getting erratic value 10, 12, 90 in weld & 60, 10, 50 in
    HAZ

    Kindly suggest your opanion  about this problem as soon as possible


    --
    To post to this group, send email to
    materials-welding@googlegroups.com
    To unsubscribe from this group, send email to
    mailto:materials-welding%2Bunsubscribe@googlegroups.com
    For more options, visit this group's bolg at
    http://materials-welding.blogspot.com/
    The views expressed/exchnaged in this group are members personel views and meant for educational purposes only, Users must take their own decisions w.r.t. applicable code/standard/contract documents.

--
To post to this group, send email to materials-welding@googlegroups.com
To unsubscribe from this group, send email to materials-welding+unsubscribe@googlegroups.com
For more options, visit this group's bolg at
http://materials-welding.blogspot.com/
The views expressed/exchnaged in this group are members personel views and meant for educational purposes only, Users must take their own decisions w.r.t. applicable code/standard/contract documents.


--
To post to this group, send email to materials-welding@googlegroups.com
To unsubscribe from this group, send email to materials-welding+unsubscribe@googlegroups.com
For more options, visit this group's bolg at
http://materials-welding.blogspot.com/
http://www.linkedin.com/groups/MaterialsWelding-122787?home=&gid=122787&trk=anet_ug_hm

The views expressed/exchnaged in this group are members personel views and meant for educational purposes only, Users must take their own decisions w.r.t. applicable code/standard/contract documents.
---
You received this message because you are subscribed to the Google Groups "Materials & Welding" group.
To unsubscribe from this group and stop receiving emails from it, send an email to materials-welding+unsubscribe@googlegroups.com.
For more options, visit
https://groups.google.com/groups/opt_out.

This message contains confidential information. To know more, please click on the following link: http://disclaimer.bureauveritas.com

No comments:

Re: [MW:35289] Welding consumable for S355J2WP material

S355 J2 WP  is a weathering structural steel  It has better atmospheric corrosion resistance. Use E 8018 - W1/W2  Electrodes This is regular...