Dear friend
You can consider DIN EN 12668-1,2,3.
Regards
On Sat, Dec 14, 2013 at 4:35 PM, Tarantula Ghosh <ghosh.tarantula@gmail.com> wrote:
In case you find anomalies in your own in-house calibration as per ASME Sec V Art 4 & 5, you are required to send the UT set to the manufacturer or client accredited institute to rectify technical problems. SNT-TC-1A says a Lev 2 can do the routine calibrations required for general job functions, but the calibration procedure shall be written by a Lev 3.--On Thu, Dec 5, 2013 at 7:02 PM, joseph mbé <mbejoseph@yahoo.fr> wrote:
--Dear expert,Could any one have the pleasure to tell me who (company or person) is authorized to perform the periodical (one year calibration) calibration of the UT machine according to the standard?best regardsJoseph Faustin MbeQA/QC EngineerTEL CMR (00237) 33129846TEL CG (00242) 057388009BP 1155 Pointe NoireYesterday is the pass, tomorrow is the future; and today? Today is the present, the gift: Enjoy it!
To post to this group, send email to materials-welding@googlegroups.com
To unsubscribe from this group, send email to materials-welding+unsubscribe@googlegroups.com
For more options, visit this group's bolg at http://materials-welding.blogspot.com/
http://www.linkedin.com/groups/MaterialsWelding-122787?home=&gid=122787&trk=anet_ug_hm
The views expressed/exchnaged in this group are members personel views and meant for educational purposes only, Users must take their own decisions w.r.t. applicable code/standard/contract documents.
---
You received this message because you are subscribed to the Google Groups "Materials & Welding" group.
To unsubscribe from this group and stop receiving emails from it, send an email to materials-welding+unsubscribe@googlegroups.com.
For more options, visit https://groups.google.com/groups/opt_out.
Tarantula
--
To post to this group, send email to materials-welding@googlegroups.com
To unsubscribe from this group, send email to materials-welding+unsubscribe@googlegroups.com
For more options, visit this group's bolg at http://materials-welding.blogspot.com/
http://www.linkedin.com/groups/MaterialsWelding-122787?home=&gid=122787&trk=anet_ug_hm
The views expressed/exchnaged in this group are members personel views and meant for educational purposes only, Users must take their own decisions w.r.t. applicable code/standard/contract documents.
---
You received this message because you are subscribed to the Google Groups "Materials & Welding" group.
To unsubscribe from this group and stop receiving emails from it, send an email to materials-welding+unsubscribe@googlegroups.com.
For more options, visit https://groups.google.com/groups/opt_out.
M. Shokri Arfaei
ISA-ISTS - Metallurgy Lab. Manager
ASNT NDT Level III
International Welding Engineer
Tel.: +98 21 66282127
Fax: +98 21 66282779
Mob.:+98 912 1394023
To post to this group, send email to materials-welding@googlegroups.com
To unsubscribe from this group, send email to materials-welding+unsubscribe@googlegroups.com
For more options, visit this group's bolg at http://materials-welding.blogspot.com/
http://www.linkedin.com/groups/MaterialsWelding-122787?home=&gid=122787&trk=anet_ug_hm
The views expressed/exchnaged in this group are members personel views and meant for educational purposes only, Users must take their own decisions w.r.t. applicable code/standard/contract documents.
---
You received this message because you are subscribed to the Google Groups "Materials & Welding" group.
To unsubscribe from this group and stop receiving emails from it, send an email to materials-welding+unsubscribe@googlegroups.com.
For more options, visit https://groups.google.com/groups/opt_out.