Vacuum Box is classified by ASME as an NDE Methode.
You may refer to ASME BPVC - Section V - Article 10, Mandatory Appendix II
- best regards
Dr. Georgios Dilintas
Authorized Nuclear Inspector
Authorized Inspector Supervisor
API 510 Inspector
I&F REGIONAL TECHNICAL MANAGER
BUREAU VERITAS HELLAS
Tel: +30 210 40 63 113/4
Fax: +30 210 40 63 118
Cell: +30 69 44 64 62 04
(See attached file: Dilintas_George.vcf)
"Kale, Bhaskar M" ---16/12/2013 08:44:22---Vacuum box leak testing is to locate leaks in a pressure boundary that cannot be directly pressurize
From: "Kale, Bhaskar M" <bmkale@gmail.com>
To: materials-welding@googlegroups.com
Date: 16/12/2013 08:44
Subject: Re: [MW:19624] Vacuum box test- API 650
Sent by: materials-welding@googlegroups.com
Vacuum box leak testing is to locate leaks in a pressure boundary that cannot be directly pressurized. Very minute leakage throughout the body (one side of wall to other side of wall) can check with vacuum box leak test.
LPT is locating the surface opening discontinuities only. And not giving the any idea if the discontinuity is throughout the body.
Both the methods have distinct benefits and can't say which one is superior. It's purely depends what type of discontinuity you are looking for; accordingly you may apply the method.
Regards,
Bhaskar
On Mon, Dec 16, 2013 at 1:57 PM, Kumar <sk7920541@gmail.com> wrote:
- Dear members,
Does the surface cracks/ sub-surface cracks cant be detected by vacuum
box tests in API 650 tanks? in that wat LPT is superior to vacuum box.
kindly share your feedbacks.
Thanks in advance,
Kumar
--
To post to this group, send email to materials-welding@googlegroups.com
To unsubscribe from this group, send email to materials-welding+unsubscribe@googlegroups.com
For more options, visit this group's bolg at http://materials-welding.blogspot.com/
http://www.linkedin.com/groups/MaterialsWelding-122787?home=&gid=122787&trk=anet_ug_hm
The views expressed/exchnaged in this group are members personel views and meant for educational purposes only, Users must take their own decisions w.r.t. applicable code/standard/contract documents.
---
You received this message because you are subscribed to the Google Groups "Materials & Welding" group.
To unsubscribe from this group and stop receiving emails from it, send an email to materials-welding+unsubscribe@googlegroups.com.
For more options, visit https://groups.google.com/groups/opt_out.
--
धन्यवाद,
भास्कर मनोहर काळे
+60149129098
--
To post to this group, send email to materials-welding@googlegroups.com
To unsubscribe from this group, send email to materials-welding+unsubscribe@googlegroups.com
For more options, visit this group's bolg at http://materials-welding.blogspot.com/
http://www.linkedin.com/groups/MaterialsWelding-122787?home=&gid=122787&trk=anet_ug_hm
The views expressed/exchnaged in this group are members personel views and meant for educational purposes only, Users must take their own decisions w.r.t. applicable code/standard/contract documents.
---
You received this message because you are subscribed to the Google Groups "Materials & Welding" group.
To unsubscribe from this group and stop receiving emails from it, send an email to materials-welding+unsubscribe@googlegroups.com.
For more options, visit https://groups.google.com/groups/opt_out.
This message contains confidential information. To know more, please click on the following link: http://disclaimer.bureauveritas.com
No comments:
Post a Comment