Tuesday, December 4, 2012

RE: [MW:16121] thinning of tubes

These according to TEMA standard after 10 % you must make retube for the Heat exchanger


From: heshamseleem7@hotmail.com
To: materials-welding@googlegroups.com
Subject: RE: [MW:16117] thinning of tubes
Date: Tue, 4 Dec 2012 08:43:33 +0200

If The Parentage of Defect pipe Exceede 10 % of the total pipe you must make plugging


Date: Sat, 1 Dec 2012 17:16:58 +0000
From: kishore103103@yahoo.com
Subject: [MW:16117] thinning of tubes
To: materials-welding@googlegroups.com

Dear all,

             How do we accept tubes thinning? We have tubes which is SA 179, 
19.05 mm and Dia, 2.11mm? and welded with tube sheets with exchangers?

            How do we accept or reject? How many tubes could be plugged if they are corroded externally? kindly give me your suggestions?

regards
kichu

--
To post to this group, send email to materials-welding@googlegroups.com
To unsubscribe from this group, send email to materials-welding+unsubscribe@googlegroups.com
For more options, visit this group's bolg at http://materials-welding.blogspot.com/
http://www.linkedin.com/groups/MaterialsWelding-122787?home=&gid=122787&trk=anet_ug_hm
 
The views expressed/exchnaged in this group are members personel views and meant for educational purposes only, Users must take their own decisions w.r.t. applicable code/standard/contract documents.
 
 

No comments:

Re: [MW:35289] Welding consumable for S355J2WP material

S355 J2 WP  is a weathering structural steel  It has better atmospheric corrosion resistance. Use E 8018 - W1/W2  Electrodes This is regular...