Tuesday, August 3, 2010

RE: [MW:6273] RE: 6259] G48 TESTING

Hi

We have used following technique while qualifying Super Duplex

 By Tig process

 

i)                    Used Pulsed tig

ii)                   Used 2% Nitrogen mixed argon

iii)                 Input as mentioned below

iv)                 Used Sandvik make Tig wire

v)                  Before testing for Corrosion test the piece was pickled and passivated

 

Regards

 

Hegde

 

From: materials-welding@googlegroups.com [mailto:materials-welding@googlegroups.com] On Behalf Of Muhammed Ibrahim PK
Sent: Tuesday, August 03, 2010 9:41 AM
To: materials-welding@googlegroups.com
Subject: Re: [MW:6272] RE: 6259] G48 TESTING

 

Hi,

 

If you do not maintain the heat input between 1.25 - 1.5 KJ/mm for super duplex stainless steel welding, G48 Testing will fail.


Thanks & Regards
Muhammed Ibrahim PK


On 3 August 2010 07:24, pgoswami <pgoswami@quickclic.net> wrote:

Dear Ganesh

 

The failures in the pitting corrosion test could be due to numerous factors. From  your query it is not at all clear, how the coupon was welded,e.g base metal, filler, welding process, technique and  what were the testing conditions&  results.

 

Why don't you post the results or summary in the forum, then the correct analysis would be be possible, otherwise it would be like a chain game.

 

Thanks.

 

Pradip Goswami,P.Eng.

Welding & Metallurgical Engineer/Specialist

Ontario Power Generation Inc.

Email-pgoswami@sympatico.ca,

pgoswami@quickclic.net

 

 


From: materials-welding@googlegroups.com [mailto:materials-welding@googlegroups.com] On Behalf Of GANESH GANESH
Sent: Monday, August 02, 2010 2:44 PM
To: materials-welding@googlegroups.com
Subject: [MW:6259] G48 TESTING

Dear Friends,

 

G48 Testing for Method C At 45 degree Celsius for 24 Hours  is requirement for super-duplex PQR (Weld Metal)

 

we have failed twice in running this testing, can some one suggest a possible solution for it.

 

Thanks,

 

With Regards,

M.S.Ganesh

 

--
To post to this group, send email to materials-welding@googlegroups.com
To unsubscribe from this group, send email to materials-welding-unsubscribe@googlegroups.com
For more options, visit this group's bolg at http://materials-welding.blogspot.com/
The views expressed/exchnaged in this group are members personel views and meant for educational purposes only, Users must take their own decisions w.r.t. applicable code/standard/contract documents.

--
To post to this group, send email to materials-welding@googlegroups.com
To unsubscribe from this group, send email to materials-welding-unsubscribe@googlegroups.com
For more options, visit this group's bolg at http://materials-welding.blogspot.com/
The views expressed/exchnaged in this group are members personel views and meant for educational purposes only, Users must take their own decisions w.r.t. applicable code/standard/contract documents.

 

--
To post to this group, send email to materials-welding@googlegroups.com
To unsubscribe from this group, send email to materials-welding-unsubscribe@googlegroups.com
For more options, visit this group's bolg at http://materials-welding.blogspot.com/
The views expressed/exchnaged in this group are members personel views and meant for educational purposes only, Users must take their own decisions w.r.t. applicable code/standard/contract documents.

No comments:

Re: [MW:35289] Welding consumable for S355J2WP material

S355 J2 WP  is a weathering structural steel  It has better atmospheric corrosion resistance. Use E 8018 - W1/W2  Electrodes This is regular...