Hi,
The following 25 Cr 35 Ni belongs to which ASTM number and specification.
Regards,
Prasanna.R.U.
From: materials-welding@googlegroups.com [mailto:materials-welding@googlegroups.com] On Behalf Of Mohamed Abdul Kareem
Sent: 22 August 2010 14:50
To: materials-welding@googlegroups.com
Subject: [MW:6623] Manufacturer PQR Test results of 25 Cr 35 Ni to SA 479 TYP 304H - furnace tubes
Hi, Manufacturer PQR Test results of 25 Cr 35 Ni to SA 479 TYP 304H - furnace tubes Tensile test of the 13 mm thick specimen results in 2.67 % & 3.7 % elongation Bend test (As per ASME IX) failed at the HAZ. Manufacturer has followed ASTM A 488 “Standard specifications for steel castings, Welding, Qualification of procedures and personnel” to qualify the procedure. Question 1. Is the PQR qualified if QW-466.19 [General notes (E)] is followed?. ”QW-466.19 - For material with less than 3 % elongation, a macro etch specimen shall be used in lieu of bend test at each bend location. Acceptance criteria shall be in accordance with QW-183(a)”. 2. Can ASTM A 488-8.2.4 be followed to qualify a procedure? “ASTM A 488-8.2.4 – Where the ductility of the parent metal is such as to render it incapable of meeting the bend test requirements, the bend test shall be conducted in the following manner: A bend bar comprised of parent metal heat treated to the ductility & strength requirements of the applicable specifications shall be bent to failure. The side bend specimen shall be then capable of being bent to within 5° of the angle thus determined.” Regards, kareem |
--
To post to this group, send email to materials-welding@googlegroups.com
To unsubscribe from this group, send email to materials-welding-unsubscribe@googlegroups.com
For more options, visit this group's bolg at http://materials-welding.blogspot.com/
The views expressed/exchnaged in this group are members personel views and meant for educational purposes only, Users must take their own decisions w.r.t. applicable code/standard/contract documents.
__________ Information from ESET NOD32 Antivirus, version of virus signature database 5383 (20100820) __________
The message was checked by ESET NOD32 Antivirus.
__________ Information from ESET NOD32 Antivirus, version of virus signature database 5386 (20100822) __________
The message was checked by ESET NOD32 Antivirus.
__________ Information from ESET NOD32 Antivirus, version of virus signature database 5386 (20100822) __________
The message was checked by ESET NOD32 Antivirus.
http://www.eset.com
__________ Information from ESET NOD32 Antivirus, version of virus signature database 5386 (20100822) __________
The message was checked by ESET NOD32 Antivirus.
http://www.eset.com
No comments:
Post a Comment