We have a WPS qualified for API 5L Gr X -65 to API -5L Gr X42,X52,X60/X65, of diameter range above 12 3/4" with wall thickness 3/16" - 3/4", welding done with SMAW process, electrode used for root is  E 7010P1 and rest with E 8018C3, "My query is whether we shall do the welding with same WPS for API 5L Gr X 60  to API 5L Gr X 60 if not we have to prepare new WPS for the mentioned material.

--
G.Murali krishnan


--
To post to this group, send email to materials-welding@googlegroups.com
To unsubscribe from this group, send email to materials-welding-unsubscribe@googlegroups.com
For more options, visit this group's bolg at http://materials-welding.blogspot.com/
The views expressed/exchnaged in this group are members personel views and meant for educational purposes only, Users must take their own decisions w.r.t. applicable code/standard/contract documents.