Hi Raghu,
The crack is on the weld.

Thanking You.
I remain.

Best Regards,
Sudipto Banerjee, BE (Mech.), C.Eng. (India), FIE

Mobile UAE: +971(0)503946212
Mobile India: +91 9987561673 (Whats app no.)



On Thursday, June 15, 2023 at 01:55:20 PM GMT+4, Raghuram Bathula <raghurambathula@gmail.com> wrote:


Dear Sudipto
what is the location of failure, weld, HAZ, BM (which side)? NDE may not detect minute linear flaws, you need run full failure investigation on samples at laboratory, 

On Thu, 15 Jun 2023 at 15:21, 'sudipto banerjee' via Materials & Welding <materials-welding@googlegroups.com> wrote:
Hi All,
One LTCS ASME DIV 1 vessel failed in Hydrotest in the joint of 2"LWNRF with Body blind flange. Its a set on type welding.
Nozzle is of SA 350 Gr. LF2 CL1 (16.7 thk) and the body blind flange of SA 765 Gr II (117 thk).
The UT test of the joint shows satisfactory.

Can anyone tell what cud be the possible reasons pls.

Thanking You.
I remain.

Best Regards,
Sudipto Banerjee, BE (Mech.), C.Eng. (India), FIE

Mobile UAE: +971(0)503946212
Mobile India: +91 9987561673 (Whats app no.)

--

--
https://materials-welding.blogspot.com/
https://www.linkedin.com/groups/122787
---
You received this message because you are subscribed to the Google Groups "Materials & Welding" group.
To unsubscribe from this group and stop receiving emails from it, send an email to materials-welding+unsubscribe@googlegroups.com.
To view this discussion on the web visit https://groups.google.com/d/msgid/materials-welding/CADxVubkwCdpydT_-e-%3DCNp%3DVefAnbdn%2BrpSYjZxvFZHkXhdOJg%40mail.gmail.com.

Comments

Popular posts from this blog

Heat tint (temper) colours on stainless steel surfaces heated in air // Heat tint

Introduction The colour formed when stainless steel is heated, either in a furnace application or in the heat affected zone of welds, is dependent on several factors that are related to the oxidation resistance of the steel. The heat tint or temper colour formed is caused by the progressive thickening of the surface oxide layer and so, as temperature is increased, the colours change.   Oxidation resistance of stainless steels However, there are several factors that affect the degree of colour change and so there is no a single table of colour and temperature that represents all cases. The colours formed can only be used as an indication of the temperature to which the steel has been heated. Factors affecting the heat tint colours formed Steel composition The chromium content is the most important single factor affecting oxidation resistance. The higher the chromium, the more heat resistant the steel and so the development of the heat tint colou...

[MW:5202] RE: 5200] NDT after PWHT

------------------------------------- Interpretation:  I‑89‑14 Subject:         Section I (1986 Edition, 1987 Addenda), PW‑11,                  NDE Prior to PWHT Date Issued:     December 15, 1988 File:            BC88‑393   Question: Does PW‑11 require that NDE be performed on welds after they have been subjected to the postweld heat treatment required by PW‑39?   Reply: No, unless the conditions described in PW‑11.2.2 exist. ---------------------------------------------- Interpretation:  VIII-1-98-09 Subject:         Section VIII, Division 1 (1995 Edition, 1996 Addenda); NDE                 ...

Materails FAQs

Q: What are equivalents for standard Q 235 B (and Q 235 A) for U-channels? (asked by: boris.vielhaber@vait.com) A: DIN Nr. = 2393 T.2, 2394 T.2, EN 10025 W. Nr. DIN 17007 = 1.0038 Design DIN 17006 = RSt 37-2, S235JRG2 (Fe 360 B) Q: What is St DIN 2391 BK material? (asked by: dmcandrews@automaticstamp.com) A: Precision steel tubes, cold-finished/hard. Q: What is C.D.W. Boiler Tube? (asked by: montydude123@yahoo.com) A: Cold Drawn Welded Boiler Tube. Q: WHAT IS W.Nr. 1.4301? PLS TELL US IN EASY LANGUAGUE (asked...