Dear Ronak :
Austenitic steels ( non L grade) are typically prone to sensitisation when subjected to temperature range of say 400 to 800 mdeg C and remained for a sufficient time at this temperature . Chrome and carbon present in IGSCC plays a major role .    

On Tue, 20 Jun 2023 at 08:47, Ronak Patel <patelronak447@gmail.com> wrote:
Dear Experts ,

We are using SS410S CLAD in Coke Drum at 450 degree temp.

Is IGC test required for SS410S material ? at present there is no requirement of IGC testing for SS410S in coke drum cladding in industry .

 As per my understanding, IGC happens in ferritic SS as well if they are exposed to high temp(450 in my case) in operation , welding or PWHT. So why SS410S is not tested for IGC as per A763 ?

How IGC is different in ferritic SS than in Austenitic SS ?


Thanks and Regards,
Ronak Patel.

--
https://materials-welding.blogspot.com/
https://www.linkedin.com/groups/122787
---
You received this message because you are subscribed to the Google Groups "Materials & Welding" group.
To unsubscribe from this group and stop receiving emails from it, send an email to materials-welding+unsubscribe@googlegroups.com.
To view this discussion on the web visit https://groups.google.com/d/msgid/materials-welding/15afeb97-8dc2-4bf1-92f2-8cfaee7a470en%40googlegroups.com.

--
https://materials-welding.blogspot.com/
https://www.linkedin.com/groups/122787
---
You received this message because you are subscribed to the Google Groups "Materials & Welding" group.
To unsubscribe from this group and stop receiving emails from it, send an email to materials-welding+unsubscribe@googlegroups.com.
To view this discussion on the web visit https://groups.google.com/d/msgid/materials-welding/CA%2BQ29OgpgtofZa1LYSNQQTkDAbhjtE-aem9XO8xWqhK6Ki46Jw%40mail.gmail.com.

No comments:

[MW:35346] Cast-iron welding

Any advice for cast iron welding Sent from Yahoo Mail for iPhone