Skip to main content

Re: [MW:33328] WELDING CONSUMABLE EXPIRY DATE

Dear Sujith

 Eletrode self life:

 1. SMAW electrodes shall not used more than 3 years  

2. Solid Wires, GTAW/GMAW/SAW-No shelf Life.  

3. Cored Wire –FCAW- No shelf life

4. SAW Fluxes- Shelf life 2-3 years depends on the flux condition. 

International Welding codes does not specify the expiry dates of welding electrodes.  example, The shelf-life depends on electrode manufacturing methods, quality control followed and how electrodes are handledThe shelf-life depends on the coating type, type of packing, storing conditions and at a temperature, humidity electrodes are stored. Based on all the these  points electrodes manufacturer decides shelf life

However following rules shall be followed about usage

1.      SMAW electrodes should be FIFO

2.       If electrode coating damaged and shows sign of peeling, rusting & cracks those shall be discarded

3.      Some of the manufacturer recommendations Electrodes older than 3years shall not be used or some manufacturer says 5years if electode stores at dry conditions and with proper packing.

some of the code manufacturer specifies Appropriate storage and handling of electrodes/ fluxes, other consumables and how Electrodes shall be shall be maintained, & most of the manufacturer's recommendations and as a good engineering practices electrode can be used 3 years Max. this time period of 3-5 years is arrived by manufacturers based on deterioration of properties due to Moisture absorption by electrodes packing, normal packing will not give required protection against moisture for longer time. Vacuum packed / hermetically sealed packed Electrodes are not affected and electrodes can be stored more time provided the vacuum/seal is not damaged. if Electrodes/ flux, are stored in a dry environment with around RH< 40-50%, deterioration effect can be minimized. So in such situations electrodes can utilized for more than 3years say up to 5years


Thanks & regards,

Srinivas Rao

welding Engineer 

 

On Friday, July 29, 2022 at 9:17:43 AM UTC+4 kannayeram gnanapandithan wrote:
Check with manufacturer

THANKS & BEST REGARDS,
KG.PANDITHAN, BE, IWE,  CSWIP 3.1,
ISO 9712 Level 2 in VT,
ASNT-Level II in PT,MT,RT & UT,
LA ISO 9001-2015,
International Welding Engineer. 
CONSULTANT-WELDING & QUALITY
Mobile no: +919940739349


On Fri, Jul 29, 2022 at 10:20 AM sujit kumar <sujitku...@gmail.com> wrote:
Dear expert,

What are the welding consumable expiry date acceptance criteria.....is there is mention anywhere in the code for the expiry of electrode and filler wire..???



Best regards.
Sujit Kumar

--
https://materials-welding.blogspot.com/
https://www.linkedin.com/groups/122787
---
You received this message because you are subscribed to the Google Groups "Materials & Welding" group.
To unsubscribe from this group and stop receiving emails from it, send an email to materials-weld...@googlegroups.com.
To view this discussion on the web visit https://groups.google.com/d/msgid/materials-welding/a5d5b9dc-5577-40fb-aa8c-653e0a647121n%40googlegroups.com.

--
https://materials-welding.blogspot.com/
https://www.linkedin.com/groups/122787
---
You received this message because you are subscribed to the Google Groups "Materials & Welding" group.
To unsubscribe from this group and stop receiving emails from it, send an email to materials-welding+unsubscribe@googlegroups.com.
To view this discussion on the web visit https://groups.google.com/d/msgid/materials-welding/9bb3f87b-bf74-47da-bd60-62aa326f6267n%40googlegroups.com.

Comments

Popular posts from this blog

Re: [MW:10788] ON PLOT PIPING & OFF PLOT PIPING

Piping systems involved for the flow lines and gathering lines from the well head isolation valve to the production facility or processing plant isolation valve are determined as OFF PLOT. ON PLOT defines piping system in the processing plant and production platform. ANSI/ASME B31.4 applies for off plot piping system. B31.4 allows the use of either API 1104 or ASME section IX (as appropriate). However, occasionally, a very small system such as piping within 500 feet of a processing plant (some client also said 400 feet) may be declared B31.3 rather than B31.4. When B31.3 is invoked, only ASME Section IX is used. before you decide which code to use for welding procedure and/or welder qualification for pipe welding, you have to know the design and construction code applicable to the system. Please read far enough into scope and diagram illustrating the application of either B31.3 and B31.4 hope this helps rgds 2011/4/21 pradip kumar sil < pradipsil@gmail.com > Dear all, ...

Materails FAQs

Q: What are equivalents for standard Q 235 B (and Q 235 A) for U-channels? (asked by: boris.vielhaber@vait.com) A: DIN Nr. = 2393 T.2, 2394 T.2, EN 10025 W. Nr. DIN 17007 = 1.0038 Design DIN 17006 = RSt 37-2, S235JRG2 (Fe 360 B) Q: What is St DIN 2391 BK material? (asked by: dmcandrews@automaticstamp.com) A: Precision steel tubes, cold-finished/hard. Q: What is C.D.W. Boiler Tube? (asked by: montydude123@yahoo.com) A: Cold Drawn Welded Boiler Tube. Q: WHAT IS W.Nr. 1.4301? PLS TELL US IN EASY LANGUAGUE (asked...

Heat tint (temper) colours on stainless steel surfaces heated in air // Heat tint

Introduction The colour formed when stainless steel is heated, either in a furnace application or in the heat affected zone of welds, is dependent on several factors that are related to the oxidation resistance of the steel. The heat tint or temper colour formed is caused by the progressive thickening of the surface oxide layer and so, as temperature is increased, the colours change.   Oxidation resistance of stainless steels However, there are several factors that affect the degree of colour change and so there is no a single table of colour and temperature that represents all cases. The colours formed can only be used as an indication of the temperature to which the steel has been heated. Factors affecting the heat tint colours formed Steel composition The chromium content is the most important single factor affecting oxidation resistance. The higher the chromium, the more heat resistant the steel and so the development of the heat tint colou...