ER70S-6 - will give you required values .
On Monday, June 29, 2020 at 6:51:43 PM UTC+4, K K wrote:
-- ER80S-Ni1 is not advised in certain environments especially Sulphur or H2S due to corrosion in presence of Ni, S, H2
On Monday, June 29, 2020 at 6:51:43 PM UTC+4, K K wrote:
Dear Experts.Can anyone suggest to according to API 582 as per TABLE - A1 has not recommended ER80S-Ni1 for AWS 5.28 GTAW process.Please explain to me in detail the table - A1 API 582 and which electrode shall I use for the below-mentioned material.PQR material - ASTM A333 Gr.6 to ASTM A350 LF2.PQR Thickness - 12.7 mm.Impact tested - -46°CThanks and regards,Kiran