Sunday, October 20, 2019

Re: [MW:30165] NEED REFERENCE CODE

Dear Minhas

What  is your specification or design requirement ??  You may opt for 100 % , sample , spot or even no RT .. ask your designer .

On Fri, 11 Oct 2019 at 11:12, Minhas Arshad <minhasarshadm08@gmail.com> wrote:
Dear Experts,

I would like to ask from all of you that i am working one of the project. I would like to confirm that butt welds with full penetration needs 100 percent radiographic test, is there any reference code? 
I have review the ISO 15614 code table 1 is about examination and testing of the test pieces should i consider this code to QIP.

Regards

--
https://materials-welding.blogspot.com/
https://www.linkedin.com/groups/122787
---
You received this message because you are subscribed to the Google Groups "Materials & Welding" group.
To unsubscribe from this group and stop receiving emails from it, send an email to materials-welding+unsubscribe@googlegroups.com.
To view this discussion on the web visit https://groups.google.com/d/msgid/materials-welding/CANOHF6tgMyhnE1vxz0iHWpwdynUFasYznL-2t62Smsmw5xpDaw%40mail.gmail.com.

--
https://materials-welding.blogspot.com/
https://www.linkedin.com/groups/122787
---
You received this message because you are subscribed to the Google Groups "Materials & Welding" group.
To unsubscribe from this group and stop receiving emails from it, send an email to materials-welding+unsubscribe@googlegroups.com.
To view this discussion on the web visit https://groups.google.com/d/msgid/materials-welding/CA%2BQ29Oh1ObuXbZTrORZcPNWiwxB-5%3DadQBjyAvBrMXuf%3DgSrkg%40mail.gmail.com.

No comments:

Re: [MW:35289] Welding consumable for S355J2WP material

S355 J2 WP  is a weathering structural steel  It has better atmospheric corrosion resistance. Use E 8018 - W1/W2  Electrodes This is regular...