7018 or 7010 Should be defined by WPS and validated by PQR.
On Tue, Jun 13, 2017 at 12:44 PM, Shankar S <sshankar.irs@gmail.com> wrote:
Dear experts,--At one particular LPG bottling plant contractor proposed WQT approval root run as E6010 and fill as E7010. I have doubt that E7018 is suppose use for fill up only.Project: Pipeline. Pipe specification PSL2( API)- Oil & Gas. Ref. standards: API 1104, ASME B 31.4/8.Please suggest accordingly.Thanks in Advance.regards,ShankarHyderabad India.