[MW:23637] Gauge width requirment in pipe certificate

Hi experts,
Can any one provide interpretation for code line SA-999( sub clause 25.2.5).
" GAUGE width required if longitudinal strip were used "
Is it mean if I used full section specimen for testing no need to mentioned anything on certificate ?


Regards
Mahesh

--
You received this message because you are subscribed to the Google Groups "Materials & Welding" group.
To unsubscribe from this group and stop receiving emails from it, send an email to materials-welding+unsubscribe@googlegroups.com.
To post to this group, send email to materials-welding@googlegroups.com.
Visit this group at http://groups.google.com/group/materials-welding.
To view this discussion on the web visit https://groups.google.com/d/msgid/materials-welding/8fcd9dd8-d0d8-4cdd-aa2f-ff3100cceb75%40googlegroups.com.
For more options, visit https://groups.google.com/d/optout.

No comments:

Re: [MW:35289] Welding consumable for S355J2WP material

S355 J2 WP  is a weathering structural steel  It has better atmospheric corrosion resistance. Use E 8018 - W1/W2  Electrodes This is regular...