Re: [MW:22960] difference between ER70 S-6 and ER70 S-3

It's Better to use ER70S-6 instead of ER70S-3 as both of in the same F no.
If you compare both MTC of the filler wire, you can find better impact properties in ER70S-6.

On Mar 9, 2015 6:07 PM, "'raouf salhi' via Materials & Welding" <materials-welding@googlegroups.com> wrote:
Dear expert ;

we have  to weld an ammonia liquid line ( temperature of service -33 °c) with ER 70 S-3 for penetration and E 7018 for filling and cap .

Our client ask to weld with ER 70 S - 6 because of better impact test proprities.

THis is true ?? please give me more details

Regards
 
SALHI Raouf
QA/QC Engineer

Tel: Morocco +212628979891
      Tunisia +21621458258

--
You received this message because you are subscribed to the Google Groups "Materials & Welding" group.
To unsubscribe from this group and stop receiving emails from it, send an email to materials-welding+unsubscribe@googlegroups.com.
To post to this group, send email to materials-welding@googlegroups.com.
Visit this group at http://groups.google.com/group/materials-welding.
To view this discussion on the web visit https://groups.google.com/d/msgid/materials-welding/830348253.1966186.1425912751788.JavaMail.yahoo%40mail.yahoo.com.
For more options, visit https://groups.google.com/d/optout.

--
You received this message because you are subscribed to the Google Groups "Materials & Welding" group.
To unsubscribe from this group and stop receiving emails from it, send an email to materials-welding+unsubscribe@googlegroups.com.
To post to this group, send email to materials-welding@googlegroups.com.
Visit this group at http://groups.google.com/group/materials-welding.
To view this discussion on the web visit https://groups.google.com/d/msgid/materials-welding/CABMP0bPud%2B_k_udw1E%2BWngMUg8JWkP7e-%3DcAOd-0G7yd%2BAe9-A%40mail.gmail.com.
For more options, visit https://groups.google.com/d/optout.

No comments:

Re: [MW:35289] Welding consumable for S355J2WP material

S355 J2 WP  is a weathering structural steel  It has better atmospheric corrosion resistance. Use E 8018 - W1/W2  Electrodes This is regular...