Dear Sir,
You have to use ER70S-6 for better impact properties (-30deg.) in the weld metal and also suggested by your client.
If you select low S & P (<0.012%) consumable in ER70S-6 class (100%CO2 shielding) than you can achieved up to -40deg. Impact too.
Rgd
P.Tiwari
QA & QC-Head
From: materials-welding@googlegroups.com [mailto:materials-welding@googlegroups.com]
Sent: Monday, March 09, 2015 8:23 PM
To: materials-welding@googlegroups.com
Subject: [MW:22958] difference between ER70 S-6 and ER70 S-3
Dear expert ;
we have to weld an ammonia liquid line ( temperature of service -33 °c) with ER 70 S-3 for penetration and E 7018 for filling and cap .
Our client ask to weld with ER 70 S - 6 because of better impact test proprities.
THis is true ?? please give me more details
Regards
SALHI Raouf
QA/QC Engineer
Tel: Morocco +212628979891
Tunisia +21621458258
--