Dear Using dead weight tester First theoritical volume of water to be calculated Filling and stabilization at half of volume air content calculation etc to be calculated After gradual increase of pressure and 24 Hours holding required Regards Rajesh
--- On Thu, 1/5/12, mohd.qce <mohd52100@gmail.com> wrote:
From: mohd.qce <mohd52100@gmail.com> Subject: [MW:13416] under ground pipeline leak testing method during hydro test To: "Materials & Welding" <materials-welding@googlegroups.com> Date: Thursday, January 5, 2012, 5:49 AM
Dear experts, Can any one give good and efficient method of underground(buried) pipe line leak testing method during hydrotest? Pipe: API 5L Gr 52 MS PSL-2. Length : Two section 50km+50km (2500 joints approx each section). Test pressure : 73.25 bar. -- To post to this group, send email to materials-welding@googlegroups.comTo unsubscribe from this group, send email to materials-welding+ unsubscribe@googlegroups.comFor more options, visit this group's bolg at http://materials-welding.blogspot.com/The views expressed/exchnaged in this group are members personel views and meant for educational purposes only, Users must take their own decisions w.r.t. applicable code/standard/contract documents.
|
--