dear Zakaria,
this grade is specially designed for cryogenic application.. additional requriment CVN Impact @ minus oc.
so you can not use as alternative G grade.
chandrakant
From: Zakaria ghrab <zakaria.ghrab@gmail.com>
To: materials-welding@googlegroups.com
Sent: Thursday, 20 October 2011 2:46 PM
Subject: [MW:12727] May E8018-C1 substitue E8018-G to weld Corten Steel
Hi all
For welding Corten steel, we have in storage E8018-C1 Electrod, may it substitue E8018-G, how can confirm ?
Regards
--
زكرياء غراب
GHRAB Zakaria
مسؤول عن الجودة
QA/QC SENAD
مشروع المحطة الحرارية ـ الوحدة الرابعة
المحمدية ـ المغرب
GHRAB Zakaria
مسؤول عن الجودة
QA/QC SENAD
مشروع المحطة الحرارية ـ الوحدة الرابعة
المحمدية ـ المغرب
To post to this group, send email to materials-welding@googlegroups.com
To unsubscribe from this group, send email to materials-welding+unsubscribe@googlegroups.com
For more options, visit this group's bolg at http://materials-welding.blogspot.com/
The views expressed/exchnaged in this group are members personel views and meant for educational purposes only, Users must take their own decisions w.r.t. applicable code/standard/contract documents.