Hi,
Please find below the extraction from ASME Sec.VIII,Div.1 - UW11.
UW-11 RADIOGRAPHIC AND ULTRASONIC
EXAMINATION
(a) Full Radiography. The following welded joints shall
be examined radiographically for their full length in the
manner prescribed in UW-51:
(1) all butt welds in the shell and heads of vessels
used to contain lethal substances [see UW-2(a)];
(2) all butt welds in vessels in which the nominal
thickness [see (g) below] at the welded joint exceeds 11⁄2
in. (38 mm), or exceeds the lesser thicknesses prescribed
in UCS-57, UNF-57, UHA-33, UCL-35, or UCL-36 for
the materials covered therein, or as otherwise prescribed
in UHT-57, ULW-51, ULW-52(d), ULW-54, or ULT-57;
however, except as required by UHT-57(a), Categories B
and C butt welds in nozzles and communicating chambers
that neither exceed NPS 10 (DN 250) nor 11⁄8 in. (29 mm)
wall thickness do not require any radiographic examination;
Thanks & Regards,
(Karthik)
Karthikeyan.S
QA/QC Manager
Getabec Energy Co.,Ltd.
379,Moo6,Soi8,Nikhomphatana,
Rayong-21180,
Thailand.
Phone: 0066 38 897035-8 (Off)
Fax: 0066 38 897034
Hand Phone: 0066 892512282
From: karthick enigoo <karthickenigoo@gmail.com>
To: materials-welding@googlegroups.com
Sent: Saturday, October 15, 2011 5:44 PM
Subject: [MW:12681] RT Required for Pipe to WNFF
To: materials-welding@googlegroups.com
Sent: Saturday, October 15, 2011 5:44 PM
Subject: [MW:12681] RT Required for Pipe to WNFF
Dear Friends,
To post to this group, send email to materials-welding@googlegroups.com
To unsubscribe from this group, send email to materials-welding+unsubscribe@googlegroups.com
For more options, visit this group's bolg at http://materials-welding.blogspot.com/
The views expressed/exchnaged in this group are members personel views and meant for educational purposes only, Users must take their own decisions w.r.t. applicable code/standard/contract documents.
I need a clarification regarding, Pipe to Flange (Weld Neck). As per my drawing Design As per ASME Sec viii, Joint efficiency - 1, Radiography - Full & PWHT considered. Size of nozzles 80NB, 350NB & 500NB Sch 60. Radiography need to be done for all nozzles.
--
Thanks & Regards,
D. Karthick
Ph.No: +91-9787300898
-- Thanks & Regards,
D. Karthick
Ph.No: +91-9787300898
To post to this group, send email to materials-welding@googlegroups.com
To unsubscribe from this group, send email to materials-welding+unsubscribe@googlegroups.com
For more options, visit this group's bolg at http://materials-welding.blogspot.com/
The views expressed/exchnaged in this group are members personel views and meant for educational purposes only, Users must take their own decisions w.r.t. applicable code/standard/contract documents.
No comments:
Post a Comment