Re: [MW:12693] RT Required for Pipe to WNFF

If the full RT is mentioned then I think RT is not req. For nozzle welds uo to size 250 NB. So in yr case  RT is req for 350 and 500 NB flanges....but chek yr client specs also and service req....if 100% RT is mentioned then RT to be done for all weld neck flanges irrespective of size........

On Oct 16, 2011 3:49 PM, "karthick enigoo" <karthickenigoo@gmail.com> wrote:

Dear Friends,
 I need a clarification regarding, Pipe to Flange (Weld Neck). As per my drawing Design As per ASME Sec viii, Joint efficiency - 1, Radiography - Full & PWHT considered. Size of nozzles 80NB, 350NB & 500NB Sch 60. Radiography need to be done for all nozzles. 

--
Thanks & Regards,                                                    
D. Karthick
Ph.No: +91-9787300898

--
To post to this group, send email to materials-welding@googlegroups.com
To unsubscribe from this group, send email to materials-welding+unsubscribe@googlegroups.com
For more options, visit this group's bolg at http://materials-welding.blogspot.com/
The views expressed/exchnaged in this group are members personel views and meant for educational purposes only, Users must take their own decisions w.r.t. applicable code/standard/contract documents.

--
To post to this group, send email to materials-welding@googlegroups.com
To unsubscribe from this group, send email to materials-welding+unsubscribe@googlegroups.com
For more options, visit this group's bolg at http://materials-welding.blogspot.com/
The views expressed/exchnaged in this group are members personel views and meant for educational purposes only, Users must take their own decisions w.r.t. applicable code/standard/contract documents.

No comments:

Re: [MW:35289] Welding consumable for S355J2WP material

S355 J2 WP  is a weathering structural steel  It has better atmospheric corrosion resistance. Use E 8018 - W1/W2  Electrodes This is regular...