Monday, July 25, 2011

RE: [MW:11907] P-11 with purging

According to ASME IX QW-256, QW-255, the deletion of backing gas is considered an essential variable. But, the addition of backing gas is not an essential variable.  This means that if you add a backing gas, a new WPS is not required by ASME IX. 
 
However, your customer's specification may require a new PQR, with a new set of mechanicals, reflecting the purged condition..


From: materials-welding@googlegroups.com [mailto:materials-welding@googlegroups.com] On Behalf Of pradip kumar sil
Sent: Saturday, July 23, 2011 9:29 AM
To: materials-welding@googlegroups.com
Subject: [MW:11877] P-11 with purging

Hi,
I have one ESTABLISHED  WPS for P-11 which is not purged by argon but as per our client specification purging is required for P-11. Can anybody tell me can i use ESTABLISHED WPS for with purged condition.  For that one, what is the criteria  & where it is written in code.
Regards
Pradip

--
To post to this group, send email to materials-welding@googlegroups.com
To unsubscribe from this group, send email to materials-welding+unsubscribe@googlegroups.com
For more options, visit this group's bolg at http://materials-welding.blogspot.com/
The views expressed/exchnaged in this group are members personel views and meant for educational purposes only, Users must take their own decisions w.r.t. applicable code/standard/contract documents.

No comments:

[MW:35346] Cast-iron welding

Any advice for cast iron welding Sent from Yahoo Mail for iPhone