Sunday, April 17, 2011

[MW:10697] Tensile requirements for API 5L X 65

Dear All
we welded to establish a procedure API 5LX65 thickness 16mm material with E7016-1 and E7018-1 esab low hydrogen electrode.
some of my frient told me it is difficult to pass tensile test requirements of API 5LX65 and coupon sample may brack in weld metal.
Please guide me if you experienced this type of failure and if the coupon bracks in weld metal what value of tensile strength is acceptable?
 
Best Regards
Zaheer
 

No comments:

[MW:34919] Welder qualification certificate

Dear All     anyone can share a format for welder certificate and card format        Thanks & Best Regards Saleem manhappulath Mob:+9665...