No - See Sc. IX, QW-424.1
"Base metals are assigned P-numbers in table QW/QB-422; metals that do not appear in table QW/QB-422 are considered to unassigned metals except as otherwize defined for base metals having the same UNS numbers. Unassigned metals shall be identified in the WPS and the PQR . . . "
In the list in QW-424.1, an unlisted material used for a PQR test only qualifies the unassigned material.
From: materials-welding@googlegroups.com [mailto:materials-welding@googlegroups.com] On Behalf Of Philip, Taiye (Lagos)
Sent: Wednesday, February 10, 2010 6:54 AM
To: materials-welding@googlegroups.com
Subject: [MW:4279] Supporting WPS
Hello gents,
Can I use a WPS qualified on A860WPHY-65 (PQR material) material to weld ASTM A 516 Gr 70 Material? (Project material) pls explain with ASME IX references.
Regards
Philip Taiye
*** WORLEYPARSONS GROUP NOTICE *** "This email is confidential. If you are not the intended recipient, you must not disclose or use the information contained in it. If you have received this email in error, please notify us immediately by return email and delete the email and any attachments. Any personal views or opinions expressed by the writer may not necessarily reflect the views or opinions of any company in the WorleyParsons Group of Companies." --
To post to this group, send email to materials-welding@googlegroups.com
To unsubscribe from this group, send email to materials-welding-unsubscribe@googlegroups.com
For more options, visit this group's bolg at http://materials-welding.blogspot.com/
The views expressed/exchnaged in this group are members personel views and meant for educational purposes only, Users must take their own decisions w.r.t. applicable code/standard/contract documents.