Why you are trying to find problems when there is not

Στις Πέμ, 1 Απρ 2021, 09:51 ο χρήστης sankar krishnan <sankar.bombay@gmail.com> έγραψε:
Dear All ,

  In our Pressure vessel project 10mm thickness plate they using (GTAW+SAW) process , They have welded GTAW with 4 mm of 10mm thickness and leave open for 1 days .. I like to Know what is the interruption limitations to stop welding Limits for <19mm thickness 