Thursday, May 26, 2016

RE: [MW:24878] E6013 not Applicable for High Thickness material

In my opinions E-6010 is a high penetrate electrode there is good for root pass for made root full penetration, usually for Pipe line downhill direction (root pass only)

 

 

 

 

Thanks and Best Regards

 

               

 

Suchin Katavut               

Managing Director

SK NDT & Inspection Co., Ltd. (SK NDT)

President

The Thai Welding and Inspection Association

Tel (+662) 327 4422 (auto) Fax. (+662) 327 4029

Email; suchin@skndt.com ,Cell Phone (+66) 81 889 4912

w.w.w.skndt.com

              

                         

The Priority is: Safety, Quarity, Service & On Time delivery

 

From: materials-welding@googlegroups.com [mailto:materials-welding@googlegroups.com] On Behalf Of Kannayeram Gnanapandithan
Sent: Thursday, May 26, 2016 11:09 AM
To: materials-welding
Subject: Re: [MW:24874] E6013 not Applicable for High Thickness material

 

JKM,   Why 6010 is preferred for root run in cross country pipeline welding?


THANKS & BEST REGARDS,

KG.PANDITHAN, IWE,  AWS-CWI, CSWIP 3.1,

CONSULTANT-WELDING & QUALITY

Mobile no: +919940739349

 

On Thu, May 26, 2016 at 9:09 AM, JIJILAL K M <jijilalkm2@gmail.com> wrote:

Dear Amit,

 

Recommending E-7018 for higher thickness structure steel welding is by considering following factors.

 

1, When thickness increase the load bearing capacity of structure increases - so flaw less welding required.

    since 7018 is low hydrogen type we can ensure less hydrogen induced weld defects by maintaining 

    proper electrode baking before welding.

 

2, As per structure code , full penetration butt weld joints required RT/UT, fillet joints need MT/PT.

    here E-7018 is better option than 6013

 

3. For thicker sections , more layer of welding /deposition required. other than 6013 , E-7018  flux having iron in fine       powdered form which will supplement 15-20% additional metal in deposited metal(called high deposition efficiency).This will help for minimum usage of  manpower , filler metal, electric power .

 

4. E-7018  required more welding skill from welder side. So only qualified welder shall be used. All this will assure you good quality welding in the end if you prefer E-7018 electrode.


JIJILAL K.M. 

QA/QC Manager,

Thai Jurong Engineering Ltd,

KCE SPP Project,Thailand

#096 786 0129

 

 

On 26 May 2016 at 00:40, Varun Ur <urvarun@gmail.com> wrote:

Dear amit

6013 can be used for higher thickness for structural weld but was D1.1 calls for pre heat for thickness above 20 MM , if you are using low hydrogen coated electrode you can skip this pre heat requirement up to certain thickness.
Also you get higher deposition rate for 7018.
And of course you can get good radiographic quality weld with 6013 also.
So weigh your pros and cons based on application limitations.

Cheers
Varun

Dear Expert

 

It has been observed that practically that E6013 electrode generally used for low thickness material i.e less than 20mm thickness however E7018 become mandatory for high thickness on the same material in structural work.
Kindly give your opinion refer to standard.

 

Regards

Amit Vishwakarma

--
http://www.linkedin.com/groups/MaterialsWelding-122787?home=&gid=122787&trk=anet_ug_hm
The views expressed/exchnaged in this group are members personel views and meant for educational purposes only, Users must take their own decisions w.r.t. applicable code/standard/contract documents.
---
You received this message because you are subscribed to the Google Groups "Materials & Welding" group.
To unsubscribe from this group and stop receiving emails from it, send an email to materials-welding+unsubscribe@googlegroups.com.
To post to this group, send email to materials-welding@googlegroups.com.
To view this discussion on the web visit https://groups.google.com/d/msgid/materials-welding/5a5cd9dd-a939-40ac-824d-1a8b8af07419%40googlegroups.com.
For more options, visit https://groups.google.com/d/optout.

--
http://www.linkedin.com/groups/MaterialsWelding-122787?home=&gid=122787&trk=anet_ug_hm
The views expressed/exchnaged in this group are members personel views and meant for educational purposes only, Users must take their own decisions w.r.t. applicable code/standard/contract documents.
---
You received this message because you are subscribed to the Google Groups "Materials & Welding" group.
To unsubscribe from this group and stop receiving emails from it, send an email to materials-welding+unsubscribe@googlegroups.com.
To post to this group, send email to materials-welding@googlegroups.com.

To view this discussion on the web visit https://groups.google.com/d/msgid/materials-welding/CAHyRLHZqX99%3D9iXBRtYv8aUdaaNkM%2BWiDMw9PT%2B8ZJ1-wXUrsQ%40mail.gmail.com.


For more options, visit https://groups.google.com/d/optout.

 

--
http://www.linkedin.com/groups/MaterialsWelding-122787?home=&gid=122787&trk=anet_ug_hm
The views expressed/exchnaged in this group are members personel views and meant for educational purposes only, Users must take their own decisions w.r.t. applicable code/standard/contract documents.
---
You received this message because you are subscribed to the Google Groups "Materials & Welding" group.
To unsubscribe from this group and stop receiving emails from it, send an email to materials-welding+unsubscribe@googlegroups.com.
To post to this group, send email to materials-welding@googlegroups.com.
To view this discussion on the web visit https://groups.google.com/d/msgid/materials-welding/CAHmEnHi_YuHv%3D6d5%2Bee3qBgJV9p4S8oke2t-LkXB-Mzx9-Om2Q%40mail.gmail.com.
For more options, visit https://groups.google.com/d/optout.

 

--
http://www.linkedin.com/groups/MaterialsWelding-122787?home=&gid=122787&trk=anet_ug_hm
The views expressed/exchnaged in this group are members personel views and meant for educational purposes only, Users must take their own decisions w.r.t. applicable code/standard/contract documents.
---
You received this message because you are subscribed to the Google Groups "Materials & Welding" group.
To unsubscribe from this group and stop receiving emails from it, send an email to materials-welding+unsubscribe@googlegroups.com.
To post to this group, send email to materials-welding@googlegroups.com.
To view this discussion on the web visit https://groups.google.com/d/msgid/materials-welding/CAJzm4eMgwj%2BGbw1s9hb7FFPC4C%3DSZg%2B0Qsi5gVP3Vi_HQ66cKA%40mail.gmail.com.
For more options, visit https://groups.google.com/d/optout.

No comments:

[MW:34919] Welder qualification certificate

Dear All     anyone can share a format for welder certificate and card format        Thanks & Best Regards Saleem manhappulath Mob:+9665...