acceptable for subsize specimen
On Monday, 23 May 2016 17:12:18 UTC+4, Biplab Pal wrote:
-- On Monday, 23 May 2016 17:12:18 UTC+4, Biplab Pal wrote:
Dear Gents,Our Construction Code is ASME B 31.3.Our Client standard is asking for the minimum impact value of 34/27 J for P1 Gr 1 & 40/32 J for P1 Gr 2 full size (10X10) specimens both Weld metal and HAZ at minimum design temperature for PQR qualification.Process- GTAW + SMAWOut MDMT is -45 Deg C.The PQR tested at -64.7 deg C and the impact values are as follows for Weld 20.33/17 J and for HAZ-1 is 41.5/35.5 & HAZ-2 is 40/50 J.Specimen size is 10X4.Is the test result acceptable for Weld zone as per client std.?We need your kind advice and code reference.
http://www.linkedin.com/groups/MaterialsWelding-122787?home=&gid=122787&trk=anet_ug_hm
The views expressed/exchnaged in this group are members personel views and meant for educational purposes only, Users must take their own decisions w.r.t. applicable code/standard/contract documents.
---
You received this message because you are subscribed to the Google Groups "Materials & Welding" group.
To unsubscribe from this group and stop receiving emails from it, send an email to materials-welding+unsubscribe@googlegroups.com.
To post to this group, send email to materials-welding@googlegroups.com.
To view this discussion on the web visit https://groups.google.com/d/msgid/materials-welding/bc8d51c8-6bf4-4f67-b4d0-4a2398cb643f%40googlegroups.com.
For more options, visit https://groups.google.com/d/optout.