Dear all
-- I witnessed DPT on incolloy 825 Weld Overlay and found some defects Like LOF, Porosity and undercuts, Defects were repaired by Subcontractor and offered and found acceptable but after one year again DPT carried out and found all the defects like porosity, LOF etc.what may be the reason.
Is it possible that Subcontractor used wrong welding procedure to carry out the repair and after some period defects gets open.
Pls convay your ideas for the above.
--
Israr Ahmed Noor Mohammed
+919930308261
+919930308261
You received this message because you are subscribed to the Google Groups "Materials & Welding" group.
To unsubscribe from this group and stop receiving emails from it, send an email to materials-welding+unsubscribe@googlegroups.com.
To post to this group, send email to materials-welding@googlegroups.com.
Visit this group at https://groups.google.com/group/materials-welding.
To view this discussion on the web visit https://groups.google.com/d/msgid/materials-welding/CAEJoza%2BbxY6T7GefTCcTO0c%3Di3SB8N83t9iKGZS_WBSkxcCf3w%40mail.gmail.com.