Thursday, February 18, 2016

[MW:24322] acceptance criteria for undercut

Hi experts in welding inspection


Is attached highlighted undercut acceptable assuming the depth in pipe edge is max 0.5 mm


pipe is welded to slip on flange from front side so it is internal weld from flange face side

construction code is ASME B31.3

Can you refer to code sections?


regards


Martin.

No comments:

[MW:35346] Cast-iron welding

Any advice for cast iron welding Sent from Yahoo Mail for iPhone