Dear Georgios sir,
code applicable is ASME sec IX & B 31.3. Impact test required. please advice
code applicable is ASME sec IX & B 31.3. Impact test required. please advice
cordially,
Jay Poojary
On 10 September 2015 at 17:58, <george.dilintas@gr.bureauveritas.com> wrote:
--is impact test a requirement?
What is the design and construction Code?
best regards
Dr. Georgios Dilintas
Authorized Nuclear Inspector
Authorized Inspector Supervisor
I&F REGIONAL TECHNICAL MANAGER
BUREAU VERITAS PIRAEUS - GREECE
Tel: +30 210 40 63 113 /4 /5
Fax: +30 210 40 63 118
Cell: +30 69 44 64 62 04
This message contains confidential information. To know more, please click on the following link: http://disclaimer.bureauveritas.com
You received this message because you are subscribed to the Google Groups "Materials & Welding" group.
To unsubscribe from this group and stop receiving emails from it, send an email to materials-welding+unsubscribe@googlegroups.com.
To post to this group, send email to materials-welding@googlegroups.com.
Visit this group at http://groups.google.com/group/materials-welding.
To view this discussion on the web visit https://groups.google.com/d/msgid/materials-welding/OFE168101B.F002AEC3-ONC2257EBC.004481A8-C2257EBC.00448CA8%40LocalDomain.
You received this message because you are subscribed to the Google Groups "Materials & Welding" group.
To unsubscribe from this group and stop receiving emails from it, send an email to materials-welding+unsubscribe@googlegroups.com.
To post to this group, send email to materials-welding@googlegroups.com.
Visit this group at http://groups.google.com/group/materials-welding.
To view this discussion on the web visit https://groups.google.com/d/msgid/materials-welding/CAAcO%3DyShhEE4rv13dAgT00%2B7i%3DhJNQyr0Ay8A_NfWTxXJeOcnA%40mail.gmail.com.
For more options, visit https://groups.google.com/d/optout.