Friday, September 25, 2015

[MW:23540] RE: 23537] Regarding failure in bend test

Hi Chirag,

                It seems the weld is sensitized. Please do micro examination to confirm the same.

 

Sent from Mail for Windows 10

 

 


From: Chirag Sandhane
Sent: 25 September 2015 11:07
To: materials-welding@googlegroups.com
Subject: [MW:23537] Regarding failure in bend test

 

 

Dear experts,

We have welded SA 240 TP310S to SA 240 TP310S plates with ER 310 filler wire. We get RT clear of the joints but get cracks in root & face bends. I am attaching photo of the same. Please give your expert advice for the same.

Thanks & regards,
Chirag Sandhane

--
You received this message because you are subscribed to the Google Groups "Materials & Welding" group.
To unsubscribe from this group and stop receiving emails from it, send an email to materials-welding+unsubscribe@googlegroups.com.
To post to this group, send email to materials-welding@googlegroups.com.
Visit this group at http://groups.google.com/group/materials-welding.
To view this discussion on the web visit https://groups.google.com/d/msgid/materials-welding/CADP96MSoaRrwQ62A_5NwSxLHaDiwm2mW7qMH_1L8DRUr%3D11nDw%40mail.gmail.com.
For more options, visit https://groups.google.com/d/optout.

 

 

No comments:

Re: [MW:35477] WPS for Furnace PWHT

The spools have 1" to 36" Piping joints. The WPS with PWHT is available only for large diameter / high thickness. can we do PWHT i...