Nilesh
-- The max thickness of plates furnished under this spec/grade is 100mm only . you can't certify it to A203 Gr E. choose another suitable grade.
On 8 October 2014 19:02, Darji Nilesh (Mumbai - Machinery) <N.Darji@ticb.com> wrote:
Dear All,
For one of our Compressor in Propylene service (MDMT = -48 Deg C), Vendor selected A 203 Gr. E material.
After order placement, Vendor has requested the following :
"Inlet Endplate is 170mm thick, and Discharge Endplate is 178mm thick.
In order to secure Low-temperature toughness for over 170mm thickness plate, we need modify weight percent of Nickel to 3.25-4.5%., instead of ASTM A203 standard as 3.25-3.75%. "
Could you please check and provide more input to accept/reject the proposal of Vendor.
With regards,
To post to this group, send email to materials-welding@googlegroups.com
To unsubscribe from this group, send email to materials-welding+unsubscribe@googlegroups.com
For more options, visit this group's bolg at http://materials-welding.blogspot.com/
http://www.linkedin.com/groups/MaterialsWelding-122787?home=&gid=122787&trk=anet_ug_hm
The views expressed/exchnaged in this group are members personel views and meant for educational purposes only, Users must take their own decisions w.r.t. applicable code/standard/contract documents.
---
You received this message because you are subscribed to the Google Groups "Materials & Welding" group.
To unsubscribe from this group and stop receiving emails from it, send an email to materials-welding+unsubscribe@googlegroups.com.
For more options, visit https://groups.google.com/d/optout.