Dear all pl I need your guide line as per your experiences; we have SS to SS job, our WPS says P8 to P8 for SMAW process, but the material is 304L to 316Ti, while we are using E308L (for root and hot) & E308L-16 (for fill & Caps), in both F-No and A-No are same. (while we have to use E318-15 or E318-17 for SMAW), need your suggestion.
2ndly for dissimilar materials SS-CS have P1-P8 electrode can we use E309L-16 for GTAW for tack welding.
Pl suggest as per AMSE-XI or else.
thanks
Jhon Ibraham
Dammam l 2nd Industrial Area
KSA