Dear All master,
Our supplier proposed material grade SM 2535 / SM 2035 for CRA OCTG with the following reservoir parameter:
Reservoir Temperature: 305 F
Reservoir Pressure: 8105 Psi
CO2 content 6.59 %
H2S Content : 0.59 %
CO2 Partial Pressure: 534 Psi
H2S Partial Pressure: 47.82 Psi
Can we use the material grade SM 2535 / 2035? Which one is better? Please advice. Thanks in advance..
Regards,
Lukman