Thursday, August 4, 2011

RE: [MW:12106] DUPLEX FERRITE CHECK

Hi,

Annexe B of API 938 C ( Use of Duplex stainless steel in Oil Refinery) may  also be referred for your case.


With Best Regards,

Jignesh R Rana




This e-mail is confidential. If you are not the intended recipient, please notify us immediately. You should not disclose its contents to any other person nor use it for any purposes.






From:        Vairamuthu Ramar <vairamuthu78@hotmail.com>
To:        <materials-welding@googlegroups.com>
Date:        04-08-11 17:02
Subject:        RE: [MW:12105] DUPLEX FERRITE CHECK
Sent by:        materials-welding@googlegroups.com




Hi,

DSS FERRITE CONTENT MEASURING STANDARD IS ASTM E562

FYKI

R Vairamuthu



From: abuhanip@labuanship.com
To: materials-welding@googlegroups.com
Subject: [MW:12098] DUPLEX FERRITE CHECK
Date: Thu, 4 Aug 2011 09:21:07 +0800

DEAR EXPERTS,
 
                IS IT STATED IN ANY CODE & STANDARD ON HOW MANY POINTS
SHALL WE TAKE FOR DUPLEX FERRITE COUNT?
 
                PLEASE GIVE ME THE SPECIFIC CLAUSE OF CODE & STANDARD IF THERE ARE ANY.
 
                YOUR COMMENT IS REALLY APPRICIATED..
 
 
 
REGARDS,


--
To post to this group, send email to materials-welding@googlegroups.com
To unsubscribe from this group, send email to materials-welding+unsubscribe@googlegroups.com
For more options, visit this group's bolg at
http://materials-welding.blogspot.com/
The views expressed/exchnaged in this group are members personel views and meant for educational purposes only, Users must take their own decisions w.r.t. applicable code/standard/contract documents.

--
To post to this group, send email to materials-welding@googlegroups.com
To unsubscribe from this group, send email to materials-welding+unsubscribe@googlegroups.com
For more options, visit this group's bolg at
http://materials-welding.blogspot.com/
The views expressed/exchnaged in this group are members personel views and meant for educational purposes only, Users must take their own decisions w.r.t. applicable code/standard/contract documents.

--
To post to this group, send email to materials-welding@googlegroups.com
To unsubscribe from this group, send email to materials-welding+unsubscribe@googlegroups.com
For more options, visit this group's bolg at http://materials-welding.blogspot.com/
The views expressed/exchnaged in this group are members personel views and meant for educational purposes only, Users must take their own decisions w.r.t. applicable code/standard/contract documents.

No comments:

[MW:34920] Tubesheet Hole step

Hello Team, I have one question any tolerance given for tubesheet Hole step. Please do needful. Regards, AP  -- https://materials-...