Re: [MW:10410] misalighnement

Yes, cl 341.3.2 does not give us acceptance criteria for misalignment. if client spec does not tell anything, then the welding procedure and technical design made by engineering will tell you the permitted misalignment.
if trimming is needed, misalignment should not exceed 1,6mm (see figure 328.4.3).
your welding procedure will also tell you the root gap and root face. 1-2mm is more advisable.

2011/3/18 raja n <rajandt1@yahoo.com>
Dear experts,
 
                  Can someone expalain me the following
1) How much root gap should be kept for piping welding as per ASME B 31.3?
2) How much misalignment allowed as per ASME B 31.3? I have refered the above code but I couldn't find the above details.
 
Thanks in advance.
 
Regards
Raja

--
To post to this group, send email to materials-welding@googlegroups.com
To unsubscribe from this group, send email to materials-welding+unsubscribe@googlegroups.com
For more options, visit this group's bolg at http://materials-welding.blogspot.com/
The views expressed/exchnaged in this group are members personel views and meant for educational purposes only, Users must take their own decisions w.r.t. applicable code/standard/contract documents.

--
To post to this group, send email to materials-welding@googlegroups.com
To unsubscribe from this group, send email to materials-welding+unsubscribe@googlegroups.com
For more options, visit this group's bolg at http://materials-welding.blogspot.com/
The views expressed/exchnaged in this group are members personel views and meant for educational purposes only, Users must take their own decisions w.r.t. applicable code/standard/contract documents.

No comments:

Re: [MW:34832] Inquiry about Single Bevel with Back Grinding

Dear Uday, As per your question that one is called with backing only,Simple both side you are welding it is backing with strip or without st...