RE: [MW:10084] failure of PQR coupon of A106 GrB in Charpy V notch

It depends on the Code and Applicable specification.

 

If it is ASME Sec.VIII Div.I, the base metal shall be of the same Heat Treated condition and of the same P number Group number classification. If the above used for PQR(only permitted), then only your HAZ & weld need to be tested for Charpy Impact.

 

In that case your PQR is accepted if either Base metal is exempted from Impact testing else it is already impact tested.

 

For the Hardness case, Please provide  detail of Base metal etc..

 

J.Gerald

 

From: materials-welding@googlegroups.com [mailto:materials-welding@googlegroups.com] On Behalf Of Mohammad Irfan Mulla
Sent: Wednesday, March 02, 2011 12:53 AM
To: materials-welding@googlegroups.com
Subject: [MW:10076] failure of PQR coupon of A106 GrB in Charpy V notch

 

Please reply with references for a senario as under,

 

a PQR has passed all mechanical tests and failed for Charpy test for base metal (weld line and HAZ charpy values are OK) then can the PQR be rejected??

 

The hardness of HAZ is almost double than weldmetal and base metal then what to do...

 



With best regards,


_________
Irfan Mulla

 

--
To post to this group, send email to materials-welding@googlegroups.com
To unsubscribe from this group, send email to materials-welding+unsubscribe@googlegroups.com
For more options, visit this group's bolg at http://materials-welding.blogspot.com/
The views expressed/exchnaged in this group are members personel views and meant for educational purposes only, Users must take their own decisions w.r.t. applicable code/standard/contract documents.


Confidentiality Notice

This communication and the information it contains:-
(a) Is intended for the person(s) or organisation(s) named above and for no other person(s) or organisation(s).
(b) May be confidential, legally privileged and protected in law. Unauthorised use, copying or disclosure of any of it may be unlawful. If you have received this communication in error, please contact us immediately by email at Postmaster@fwuk.fwc.com.

No comments:

Re: [MW:35289] Welding consumable for S355J2WP material

S355 J2 WP  is a weathering structural steel  It has better atmospheric corrosion resistance. Use E 8018 - W1/W2  Electrodes This is regular...