Hi
This is to get Ferrite and Austenite in correct proportion i.e. 35-45% Ferrite .This also to get weld properties as per GS 8 spec.
Regards
Hegde P.B.
From: materials-welding@googlegroups.com [mailto:materials-welding@googlegroups.com] On Behalf Of rajagopal kannan
Sent: Tuesday, August 18, 2009 2:35 PM
To: materials-welding@googlegroups.com
Subject: [MW:2959] nitrogen
Hi,
I could see in a client spec. insisting the use of 98% Ar and 2% Nitrogen gas mixture for backing and shielding of duplex steel welding.
What could be the significance of using 2% Nitrogen?
How it is technically advantageous over use of single argon gas?
Thanks and Regards,
K.RAJAGOPAL
--~--~---------~--~----~------------~-------~--~----~
To post to this group, send email to materials-welding@googlegroups.com
To unsubscribe from this group, send email to materials-welding-unsubscribe@googlegroups.com
For more options, visit this group's bolg at http://materials-welding.blogspot.com/
The views expressed/exchnaged in this group are members personel views and meant for educational purposes only, Users must take their own decisions w.r.t. applicable code/standard/contract documents.
-~----------~----~----~----~------~----~------~--~---