Dear Sihva, We used pipeline in Oman the same material with Bohler Foxcel E-6010 (only root), hot pas fill and cap Bohler Foxcel85 E8010-P1 also the same electodes Baku-tibilisi- ceyhan pipeline. there was no any problem occured. you needed to be carry on preheat temperature min.50celcius degree and the time between root pass and hot pass. Note that (when the root welding is started pipe cannot move any direction after the hot pass complete). Best Regards, Ayhan GEDUK Turkey Mobile:+90 5358811933 --- On Mon, 17/8/09, kayvan alyari <k.alyari@gmail.com> wrote:
|